ACR Electronics SmartReader Plus Specifications Page 93

  • Download
  • Add to my manuals
  • Print
  • Page
    / 117
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 92
SmartReader Plus Data Logger
84
Copyright © 2010 ACR Systems Inc. All Rights Reserved.
wire; red and white leads are stripped and tinned.
Figure C-3: ET-081 Probe Resolution
ET-086 Oven Temperature Probe
Description: NTC thermistor and cable potted into the end of a 22mm
(7/8") long by 5.5mm (7/32") diameter nickel-plated eyelet.
R125 Value: 26,266 ohms
Equation: 48
Range: 70 to 255°C (155 to 490°F)
Max. Temp.: 275°C (525°F)
Resolution: Refer to Figure C-4
Accuracy: ±1°C (1.8°F) from the temperature values listed in Table C-1
over the range of 70 to 255°C (155 to 490°F)
Cable: 6m (20ft) standard length with twisted-pair moisture-proof
Teflon®- coated glass yarn wire; white leads are stripped and
Page view 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 116 117

Comments to this Manuals

No comments