20 Programmer’s Guide
4. With PGAIN increased to 0.001, motor responsiveness has
increased (Figure 4) and the over-damping has decreased
slightly. As there is no significant change to the settling, there is
no need to adjust the DGAIN. However, there is still room for
improvement on motor response.